<< Click to Display Table of Contents >> Navigation: Irinos EC Users Manual > Setup & First Steps > Web-Server |
The Irinos system has an integrated web server that serves as a setup and diagnostic tool. The web server is accessed from a web browser such as Internet Explorer, Firefox, Chrome or Opera. Enter the IP address of the Irinos system in the address line of the web browser (default 192.168.3.99).
The presentation of the web pages was successfully tested with the web browsers InternetExplorer 11, Firefox and Chrome. Due to the different interpretation of standards, a flawless function cannot be guaranteed with all browsers and browser versions. |
There are 3 different websites available:
On the "Measurement" web page, the current measured values of the measurement inputs and the current status of the digital inputs/outputs are displayed live (update rate approx. 4 Hz).
This allows:
oThe measurement probes can be adjusted and testes without the availability of the measurement software.
oThe measurement values shown on the webserver can be compared to those, which are shown by the measurement software.
Please note for inductive probes: The displayed unit is valid for standard probes. For probes with longer travel (e.g. ±5mm) and different sensitivity, a manual conversion is required.
The website "Inventory" displays an overview of all Irinos boxes available in the Irinos system with the most important box information:
Information |
Example |
Description |
---|---|---|
Serial |
I018023 |
Serial number of the Irinos-Box |
Device |
EC-TFV-8-TESA-M16-EPI |
Description of the Irinos-Box |
MAC Address |
A0-BB-3E-E0-06-2C |
Unique MAC address of the Irinos-Box |
Order Number |
828-6050 |
Order number. It always begins with 8. |
Firmware Version |
V2.0.0.18 |
Firmware version |
Hardware Version |
V1.2 |
Hardware version |
Hardware Revision |
1 |
Hardware compatibility code for firmware update |
Sample Period |
250 µs |
Internal sampling period in µs |
Channels |
8 channels (16-bit) |
Number of measurement channels and their internal data type |
Digital Inputs |
16 |
Number of digital input bits |
Digital Outputs |
16 |
Number of digital output bits |
The Diagnostic web page displays the contents of the diagnostic memory of the individual Irinos boxes:
Column |
Example |
Explanation |
---|---|---|
Diagnostic-Id |
Sine-oscillator (15) |
Type of diagnostic event. |
System Time |
8935067150 |
Link-Zeit in µs since power-on of the Irinos-Systems. (This internal time is identical for all Irinos Boxes) |
Abs. Time |
2019-07-22 12:21:05:994 |
Date and time when the event occurred. Year-Month-Day Hour:Minute:Second:Millisecond |
Module |
0x2000 |
Additional Information for support requests. |
Line |
570 |
|
Event |
Probe short circuit. To identify the defective probe, remove each probe until this error is gone. |
Help text for the event. |
Firmware-Version |
V2.0.0.18 |