NMX_GetChannelInfo_1

<< Click to Display Table of Contents >>

Navigation:  NmxDLL Reference Guide > API (programming interface) > Get device information >

NMX_GetChannelInfo_1

This function is used to read information about a measurement channel. If supported by the probe, additional probe information is provided (digital probe type plate).

 

Definition


NMX_STATUS NMX_GetChannelInfo_1(

 NMX_PHANDLE pHandle,

 unsigned long ulChannelNo,

 unsigned long* pulChannelType,

 unsigned long* pulNDigits,

 unsigned long* pulBoxNo,

 unsigned long* pulReserved,

 unsigned long* pulBoxChannelNo,

 signed long* pslRawDataType,

 signed long* pslFactNumerator,

 signed long* pslFactDenominator,

 float* pflFactDigitsToUnit,

 char* pcUnit, unsigned long ulSizeofUnit,

 char* pcOrderNo, unsigned long ulSizeofOrderNo,

 char* pcSerialNo, unsigned long ulSizeofSerialNo);

 

Parameter


pHandle

Connection Handle.

ulChannelNo

Number of the measurement channel.
The first channel has the number 0.
Having a device with 8 measurement channels, these are numbered 0..7.

pulChannelType

Measurement channel type. See below for a list of channel types.

pulNDigits

Recommended max. number of decimal places for the measurement value, converted to its unit.
E.g. pulNDigits = 2 --> 54.17µm

pulBoxNo

Number of the Box, where the measurement channel is located.

pulReserved

Reserved for future use.

pulBoxChannelNo

Number of the channel within its measurement box.
Numbering starts at 1 with each Box.
 
Example: In a system with 2 Boxes à 8 Channels, Channel number 11 is the 4th channel of the second box. Thus the value 4 is returned.

pslRawDataType

Data type, in which the measurement data is acquired.
0 = Unknown (DTRAW_UNKNOWN)
1 = signed 8 Bit (DTRAW_SINT08)
2 = signed 16 Bit (DTRAW_SINT16)
4 = signed 32 Bit (DTRAW_SINT32)
8 = signed 64 Bit (DTRAW_SINT64)
See the data types chapter for more information.

pslFactNumerator

Numerator of the factor, which is used for converting the digit value into its physical unit.
For some channel types, the physical unit is unknown by the device. Then this value is 1.
For some channel types, e.g. inductive probes, this is also the maximum stroke, which the probe has.

pslFactDenominator

Denominator of the factor, which is used for converting the digit value into its physical unit.
For some channel types, the physical unit is unknown by the device. Then this value is 1.

pflFactDigitsToUnit

= pslFactNumerator / pslFactDenominator.
Floating point representation of the factor, which is used for converting the digit value into its physical unit.
(ANSI/IEEE Std 754-1985; IEC-60559:1989: single precision 32 Bit)

pcUnit

ASCII based string with the channels physical unit (or "Digits" if the unit is unknown). The maximum string length is 9 characters (8 + Termination).

ulSizeofUnit

Maximum size of pcUnit in Bytes/Characters.

pcOrderNo

ASCII based string with the probe/sensors order number, if available. The maximum string length is 17 characters (16 + Termination).

ulSizeofOrderNo

Maximum size of pcOrderNo in Bytes/Characters.

pcSerialNo

ASCII based string with the probe/sensors serial number, if available. The maximum string length is 17 characters (16 + Termination).

ulSizeofSerialNo

Maximum size of pcSerialNo in Bytes/Characters.

 

Typical function call (C example)


NMX_GetChannelInfo_1(pHandle, ulChannel, &ulChannelType, &ulNDigits, &ulBoxNo, NULL, &ulBoxChannelNo, &slRawDataType, &slFactNumerator, &slFactDenominator, &flFactDigitsToUnit, acUnit, sizeof(acUnit), acOrderNo, sizeof(acOrderNo), acSerialNo, sizeof(acSerialNo));

 

Channel types


The channel type allows identifying the channel and/or probe type. The list is constantly expanded. Currently the following types are supported:

Type

Hex value

Description

CHANNEL_TYPE_UNKNOWN

0x0000

No channel type available

CHANNEL_TYPE_TESA2000

0x0100

Tesa HalfBridge or compatible, 13 kHz, 3Veff, Default Stroke: ±2mm at 73.75mV/V/mm

CHANNEL_TYPE_TESA2000_LIN

0x0101

Tesa HalfBridge or compatible, 13 kHz, 3Veff, Linearized, Max Stroke ±2mm

CHANNEL_TYPE_TESA3000_LIN

0x0103

Tesa HalfBridge or compatible, 13 kHz, 3Veff, Linearized, Max. Stroke ±3mm

CHANNEL_TYPE_TESA5000_LIN

0x0105

Tesa HalfBridge or compatible, 13 kHz, 3Veff, Linearized, Max. Stroke ±5mm

CHANNEL_TYPE_IET200

0x0110

Knäbel IET, 50 kHz, 1.5Veff, Default Stroke: ±200µm

CHANNEL_TYPE_SOLVDT1000

0x0120

Solartron LVDT or compatible, 5 kHz, 3Veff, Default Stroke: ±1mm at 200mV/V/mm

CHANNEL_TYPE_SOLVDT100E1M

0x0121

Solartron customized type.

CHANNEL_TYPE_FEINP1000

0x0130

Feinprüf / Mahr, 20 kHz, 3Veff, Default Stroke: ±1mm

CHANNEL_TYPE_MARPLVDT

0x0140

Marposs LVDT, Default Stroke: ±1mm

CHANNEL_TYPE_INCTTL

0x0200

Incremental Encoder TTL/RS422

CHANNEL_TYPE_INC1VSS

0x0210

Incremental Encoder 1Vpp

CHANNEL_TYPE_AIND10

0x0300

Analogue Input ±10V Differential

CHANNEL_TYPE_TEMPKC

0x0400

Thermocouple, K-Type

CHANNEL_TYPE_LASER

0x0500

Laser-Sensor (Sub-Types available).

 

.Net DLL specific implementation


NMX_MSTATUS GetChannelInfo_1(

                 System::IntPtr pHandle,

                 System::UInt32 ulChannelNo,

                 System::UInt32 %pulChannelType,

                 System::UInt32 %pulNDigits,

                 System::UInt32 %pulBoxNo,

                 System::UInt32 %pulReserved,

                 System::UInt32 %pulBoxChannelNo,

                 System::Int32 %pslRawDataType,

                 System::Int32 %pslFactNumerator,

                 System::Int32 %pslFactDenominator,

                 System::Single %pflFactDigitsToUnit,

                 System::String ^%strUnit,

                 System::String ^%strOrderNo,

                 System::String ^%strSerNo);

No Length/Sizeof-Parameters are required for the strings, since this information is not required in a .Net environment. They are directly returned as Unicode-strings. Hence no additional conversion is required.

 

Comments


It is good practice reading the channel count first. Then read the channel information for each channel.

The function only returns values, if the function return code is NST_SUCCESS. Otherwise the values remain unchanged.